ETL-1000 Cooling System
Treatment Concentrate
Diesel Engine Corrosion Inhibitor
PRODUCT BENEFITS
?
Designed to protect cast iron diesel engine
cooling systems
?
Contains additives to protect against sludge and
mineral scale formation
?
Prevents overheating
?
Effective against liner pitting and cavitation
erosion
?
Not harmful to radiator or heater connecting
hoses, diesel liner seals and ?O-ring
?
Recommended and used by major diesel engine
manufacturers throughout the world
PRINCIPAL USES
ETL-1000
functions as a protective, film-forming
corrosion inhibitor and scale suppressant to keep engines clean and free from
scale, and reduces downtime and maintenance costs.
The product protects cooling systems against
corrosion, liner pitting, cavitation-erosion, mineral scale deposits and
electrolysis.
GENERAL DESCRIPTION
Characteristics:
Color ? Red
Odor ? Slight
Solubility in water ? Soluble in all proportions
Refer to the ETL-1000 Material Safety
Data Sheet for additional chemical and physical properties.
INSTRUCTIONS FOR USE
1. Before Treatment: Drain, chemically
clean and flush the cooling system before charging with
ETL-1000
to remove dirt, deposits, oil and rust
particles.
2. Initial Dosage: Add ETL-1000 to
the system at an initial dosage of 1 pint for every
4 gallons of cooling system capacity.
3. Preventive Maintenance Treatment:
Top Off
? Never top off with plain water. Always top up
with a mixture of one part ETL-1000 for every 32 parts of clean, soft
water.
Make Up Dosage
? Maintain the correct treatment level of
inhibitor level by adding additional
ETL-1000
inhibitor:
?For systems less than 20 gallons: One pint for
?every 4 gallon capacity, every 12,000 miles or
?250 hours.
?For systems larger than 20 gallons: One pint
for
?every 20 gallons capacity, every routine
service.
Product Life
? ETL-1000, once in use, should be
drained and flushed once every 12 months.
TESTING
For control, use a test kit available from
Enertech Labs that tests for glycol and nitrite.
Maintain a nitrite reserve of 1000?1500 ppm.
HANDLING AND STORAGE
Read the label and Material Safety Data Sheet
for complete handling information before using this product.
ETL-1000
may be stored up to one year. The product
becomes ?mushy? at ?15?F
(?26?C)
and is satisfactory for use after complete thawing.
QUALITY
This product is made under ISO9002.
REMARKS
Technical representatives can assist in the
evaluation and implementation of a treatment program involving this product.

Send mail to
sales@enertechlabs.com with
questions or comments about this web site.
Copyright © 2003, 2004, 2005, 2006, 2007, 2008, 2009
Enertech Labs, Inc.
Last modified:
01/12/09
|